Home / Products / Zeta Power™

Cooling-water side

Zeta Power™ System: keeps condenser tubes clean and the approach temperature low, effectively improving chiller performance.

35 kV Zeta Power electrode rods installed in the cooling tower make particles in the water repel each other and stay dispersed, so they do not form scale or biofilm on equipment surfaces. Installation needs no shutdown, and each rod uses only a few watts.

Zeta Power™

kV

35 kVDC · 0.11 mAZTPS-35K

W

4 WZTPS-35K

cm

94 cm · 1.5″ NPTZT36S

Principle

How it works

  1. Ceramic electrode rods in a protective casing are placed directly in the cooling-tower basin.
  2. A 35 kV DC high-voltage, low-current power supply creates an electrostatic field in the water.
  3. The zeta potential of colloidal particles in the water rises, so the particles repel each other and stay dispersed, are less likely to deposit as scale or biofilm, and are eventually removed with the blowdown.
  4. Condenser tubes stay clean and the approach temperature drops, so the chiller uses less power while cleaning and maintenance costs go down.
35 kV DC

Your existing chemicals and dosage stay the same

Your existing chemicals and dosage remain unchanged; installing Zeta Power™ requires no additional chemicals and no change in dosage.


Proven long term: the earliest Zeta Power System installations have been running for 20 years and remain in efficient service today.

Applications

One technology, many applications

Zeta Power™ electrode rod in a cooling-tower basin

Cooling water

Cooling towers & chillers

Condenser tubes stay clean and the approach temperature stays low, so chillers use less power and need less cleaning and maintenance.

See specifications →

Scrubber packing rings (after Zeta Power™ installation)

Scrubber circulating water

Wet scrubbers

Rods are installed in the circulation tank with no downtime, helping filters and packing stay cleaner between cleanings so pressure drop is slower to climb.

Wet scrubbers →

Stainless-steel casings for Zeta Power™ electrode rods

Wastewater treatment

PCB copper wastewater

Rods installed in the equalization tank help your existing coagulant work within the residence time you have. Pilot projects are open now.

PCB wastewater →

Cooling-water corrosion: deposits and biofilm can shield metal from corrosion inhibitors and promote local corrosion. Keeping surfaces clean helps your existing inhibitor program work.

Specifications

Electrode ZT36SVitrified ceramic tube + stainless-steel fitting · overall length 94 cm (wetted length 84 cm) · diameter 3.81 cm · 1.5″ NPT
Power supply ZTPS-35KInput AC 85–305 V · output 0–35 kVDC, 0.11 mA, 4 W · operating temperature −40 to 65°C · multiple electrodes can be daisy-chained
Other power options24 V DC battery, or solar panel + battery
MaintenanceCheck the power-supply LED · verify the output with a 40 kV test probe · keep the insulating cap filled with dielectric grease
Zeta Power™ electrode rod in a stainless-steel protective casing, placed in the cooling-tower basin
Zeta Power™ electrode casing submerged in the cooling-tower basin

The electrode rods sit in a protective casing placed directly in the cooling-tower basin.

Installation

Installation steps

Step 1Site assessment

Step 2Measure COP before

Step 3Clean the condenser tubes and cooling tower

Step 4Install Zeta Power

Step 5Keep your existing chemical program

Step 6Measure COP after

Step 7Submit report

Results

5–15% energy savings

Used together with FRIGAID®, combined savings of 5–15% on chiller electricity costs (manufacturer’s figure; actual results depend on equipment condition). Mature, proven technology – years of successful projects and rigorously measured before-and-after COP comparisons.

Source: en.frigaid.com.tw/about/6.htm

Before and after installation

  • Cooling-tower basin and walkway (before installation)
    Before installation
    Cooling-tower basin and walkway (after installation)
    After installation

    Zeta Power™Cooling-tower basin and walkway

  • Cooling-tower fill (before installation)
    Before installation
    Cooling-tower fill (after installation)
    After installation

    Zeta Power™Cooling-tower fill

  • Chiller condenser tube sheet (before installation)
    Before installation
    Chiller condenser tube sheet (after installation)
    After installation

    Zeta Power™Chiller condenser tube sheet

Global clients of FRIGAID® & Zeta Power™

Semiconductor & electronics

  • TSMC
  • Intel
  • Foxconn (Hon Hai)
  • GlobalFoundries
  • UMC
  • Western Digital
  • ASE
  • Amkor
  • Pegatron
  • AUO
  • Macronix
  • Nanya Technology
  • Powerchip
  • VIS
  • SPIL
  • Unimicron
  • KYEC
  • ChipMOS
  • Chipbond
  • United Semiconductor
  • JHICC
  • Hana Microelectronics
  • Lingsen Precision
  • Unitech PCB

Wafers & materials

  • Shin-Etsu
  • Formosa Plastics
  • GlobalWafers
  • Siltronic
  • Formosa SUMCO
  • Nan Ya Plastics
  • Formosa Chemicals & Fibre
  • Wafer Works

Malls & retail

  • MTR Malls (Hong Kong)
  • Far Eastern SOGO
  • Big C (Thailand)
  • Citygate Outlets (Swire)
  • Far Eastern Department Stores
  • Far Eastern Big City (Hsinchu)
  • TaiMall (Taoyuan)
  • Walter Mart (Philippines)
  • Plaza Tasek (Johor Bahru)

Hotels

  • Holiday Inn Golden Mile (Hong Kong)
  • Holiday Inn (Nashville)
  • Novotel Bangkok Siam Square
  • Mayfair Hotel (Shanghai)
  • The Landis Taichung
  • Evergreen Laurel Hotel (Keelung, Taichung)
  • Grand Hi-Lai Hotel (Kaohsiung)
  • Howard Prince Hotel (Taichung)
  • Ocean Hotel (Hualien)

Hong Kong landmarks

  • Hong Kong International Airport
  • HSBC
  • Hang Seng Bank
  • PCCW
  • Cyberport
  • Towngas
  • Hong Kong Central Library
  • Hong Kong International School
  • Tuen Mun Hospital
  • Eastern Hospital

FAQ

Is Zeta Power™ an ultrasonic device?

No. It uses an electrostatic field generated by high-voltage electrodes.

Do we need to change our existing water treatment or dosage after installation?

No. Your existing chemicals and dosage stay the same; installing Zeta Power™ requires no additional chemicals and no change in dosage.

Does it remove rust?

No. Zeta Power™ is not a rust-removal device.

Does installing the electrodes require a shutdown?

No. The electrodes are simply placed in the cooling-tower basin; the chillers keep running.

Contact us

Book a complimentary chiller plant site assessment

Contact our team in Thailand directly.

6/1 Moo 11, Malaiman Rd., Wang Nam Khiao, Kamphaeng Saen, Nakhon Pathom 73140, Thailand

Zeta contact form (EN)