Cooling-water side
Zeta Power™ System: keeps condenser tubes clean and the approach temperature low, effectively improving chiller performance.
35 kV Zeta Power electrode rods installed in the cooling tower make particles in the water repel each other and stay dispersed, so they do not form scale or biofilm on equipment surfaces. Installation needs no shutdown, and each rod uses only a few watts.
Zeta Power™
kV
35 kVDC · 0.11 mAZTPS-35K
W
4 WZTPS-35K
cm
94 cm · 1.5″ NPTZT36S
Principle
How it works
- Ceramic electrode rods in a protective casing are placed directly in the cooling-tower basin.
- A 35 kV DC high-voltage, low-current power supply creates an electrostatic field in the water.
- The zeta potential of colloidal particles in the water rises, so the particles repel each other and stay dispersed, are less likely to deposit as scale or biofilm, and are eventually removed with the blowdown.
- Condenser tubes stay clean and the approach temperature drops, so the chiller uses less power while cleaning and maintenance costs go down.
Your existing chemicals and dosage stay the same
Your existing chemicals and dosage remain unchanged; installing Zeta Power™ requires no additional chemicals and no change in dosage.
Proven long term: the earliest Zeta Power System installations have been running for 20 years and remain in efficient service today.
Applications
One technology, many applications

Cooling water
Cooling towers & chillers
Condenser tubes stay clean and the approach temperature stays low, so chillers use less power and need less cleaning and maintenance.

Scrubber circulating water
Wet scrubbers
Rods are installed in the circulation tank with no downtime, helping filters and packing stay cleaner between cleanings so pressure drop is slower to climb.

Wastewater treatment
PCB copper wastewater
Rods installed in the equalization tank help your existing coagulant work within the residence time you have. Pilot projects are open now.
Cooling-water corrosion: deposits and biofilm can shield metal from corrosion inhibitors and promote local corrosion. Keeping surfaces clean helps your existing inhibitor program work.
Specifications
Electrode ZT36S | Vitrified ceramic tube + stainless-steel fitting · overall length 94 cm (wetted length 84 cm) · diameter 3.81 cm · 1.5″ NPT |
|---|---|
Power supply ZTPS-35K | Input AC 85–305 V · output 0–35 kVDC, 0.11 mA, 4 W · operating temperature −40 to 65°C · multiple electrodes can be daisy-chained |
| Other power options | 24 V DC battery, or solar panel + battery |
| Maintenance | Check the power-supply LED · verify the output with a 40 kV test probe · keep the insulating cap filled with dielectric grease |
Installation
Installation steps
Step 1Site assessment
Step 2Measure COP before
Step 3Clean the condenser tubes and cooling tower
Step 4Install Zeta Power
Step 5Keep your existing chemical program
Step 6Measure COP after
Step 7Submit report
Results
5–15% energy savings
Used together with FRIGAID®, combined savings of 5–15% on chiller electricity costs (manufacturer’s figure; actual results depend on equipment condition). Mature, proven technology – years of successful projects and rigorously measured before-and-after COP comparisons.
Before and after installation
Zeta Power™Cooling-tower basin and walkway
Zeta Power™Cooling-tower fill
Zeta Power™Chiller condenser tube sheet
Global clients of FRIGAID® & Zeta Power™
Semiconductor & electronics
- TSMC
- Intel
- Foxconn (Hon Hai)
- GlobalFoundries
- UMC
- Western Digital
- ASE
- Amkor
- Pegatron
- AUO
- Macronix
- Nanya Technology
- Powerchip
- VIS
- SPIL
- Unimicron
- KYEC
- ChipMOS
- Chipbond
- United Semiconductor
- JHICC
- Hana Microelectronics
- Lingsen Precision
- Unitech PCB
Wafers & materials
- Shin-Etsu
- Formosa Plastics
- GlobalWafers
- Siltronic
- Formosa SUMCO
- Nan Ya Plastics
- Formosa Chemicals & Fibre
- Wafer Works
Malls & retail
- MTR Malls (Hong Kong)
- Far Eastern SOGO
- Big C (Thailand)
- Citygate Outlets (Swire)
- Far Eastern Department Stores
- Far Eastern Big City (Hsinchu)
- TaiMall (Taoyuan)
- Walter Mart (Philippines)
- Plaza Tasek (Johor Bahru)
Hotels
- Holiday Inn Golden Mile (Hong Kong)
- Holiday Inn (Nashville)
- Novotel Bangkok Siam Square
- Mayfair Hotel (Shanghai)
- The Landis Taichung
- Evergreen Laurel Hotel (Keelung, Taichung)
- Grand Hi-Lai Hotel (Kaohsiung)
- Howard Prince Hotel (Taichung)
- Ocean Hotel (Hualien)
Hong Kong landmarks
- Hong Kong International Airport
- HSBC
- Hang Seng Bank
- PCCW
- Cyberport
- Towngas
- Hong Kong Central Library
- Hong Kong International School
- Tuen Mun Hospital
- Eastern Hospital
FAQ
Is Zeta Power™ an ultrasonic device?
No. It uses an electrostatic field generated by high-voltage electrodes.
Do we need to change our existing water treatment or dosage after installation?
No. Your existing chemicals and dosage stay the same; installing Zeta Power™ requires no additional chemicals and no change in dosage.
Does it remove rust?
No. Zeta Power™ is not a rust-removal device.
Does installing the electrodes require a shutdown?
No. The electrodes are simply placed in the cooling-tower basin; the chillers keep running.
Contact us
Book a complimentary chiller plant site assessment
Contact our team in Thailand directly.
6/1 Moo 11, Malaiman Rd., Wang Nam Khiao, Kamphaeng Saen, Nakhon Pathom 73140, Thailand