Authorized distributor of FRIGAID® & Zeta Power™ in Thailand
Wait, you can boost chiller efficiency without shutting it down?
Zeta Eco Technology brings FRIGAID® and Zeta Power™ to Thailand. Working on the refrigerant side and the cooling-water side together saves a combined 5–15%* on cooling-system electricity costs.
Mature, proven technology – years of successful projects and rigorously measured before-and-after COP comparisons.
Suitable for
- Hotels & resorts
- Shopping malls
- Hospitals
- Government buildings
- Semiconductor fabs
- PCB plants
- Electronics manufacturing
- Data centers
- District cooling
- Most large chiller / cooling-tower systems
Your chiller plant · both sides covered
Refrigerant sideFRIGAID®
Cooling-water sideZeta Power™
Mechanical equipmentFRIGAID® Lubricant
5–15%
Chiller electricity savings,
both sides combined*
4,500,000+ RT
Total chiller tonnage worldwide
with FRIGAID® installed (as of 2025)
500,000 m³/hr
Cooling-tower circulating water flow
with Zeta Power™ installed worldwide
The problem
Why do chillers and cooling towers use more power over time?
1
Refrigerant side: oil film
After long hours of operation, refrigerant oil, carbon deposits and impurities form an oil film on the inner tube walls of the evaporator and condenser, and heat transfer gradually deteriorates.
2
Cooling-water side: scale and biofilm
Impurities and particles in the cooling water adhere to condenser surfaces and form scale and biofilm. Heat rejection suffers, the approach temperature rises and the chiller uses more power.
How can a 24/7 cooling system save energy?
Solutions
Three products for three parts of the system
Cooling-water side
Zeta Power™: keeps condensers clean for optimal heat rejection and a low approach temperature.
A 35 kV electrostatic electrode installed in the cooling-tower basin keeps particles in the water dispersed, so they do not form scale or biofilm on the condenser tubes. Installation needs no shutdown, no additional chemicals and no change to your current chemical dosage.
Refrigerant side
FRIGAID®: one installation restores refrigerant-side heat-transfer efficiency.
A polarized refrigerant oil additive. Highly heat-conductive polarized molecules attach themselves to metal surfaces, clearing the oil film from evaporator and condenser tube walls and improving lubricity. Real results are measured, not estimated.
Mechanical equipment
FRIGAID® Lubricant: effectively reduces friction and cuts motor/machinery energy use.
Added at 3–5% to the lubricating oil of air compressors, blowers, water pumps and cooling-tower fans.
Applications
One technology, many applications

Cooling water
Cooling towers & chillers
Condenser tubes stay clean and the approach temperature stays low, so chillers use less power and need less cleaning and maintenance.

Scrubber circulating water
Wet scrubbers
Rods are installed in the circulation tank with no downtime, helping filters and packing stay cleaner between cleanings so pressure drop is slower to climb.

Wastewater treatment
PCB copper wastewater
Rods installed in the equalization tank help your existing coagulant work within the residence time you have. Pilot projects are open now.
Cooling-water corrosion: deposits and biofilm can shield metal from corrosion inhibitors and promote local corrosion. Keeping surfaces clean helps your existing inhibitor program work.
How a project runs
Every project is customized, with data measured before and after
1
Complimentary chiller plant site assessment
2
Measure COP before
3
Installation
Hassle-free installation – designed for facilities that cannot switch off their air conditioning.
4
Measure COP after and submit a report
Long-term follow-up measurement is available after installation.
Applications
Broad compatibility and applicability
Hotels & resorts
Lower kW/RT and water use, guests stay comfortable, and installation needs no shutdown.
Shopping malls
Air conditioning is one of a mall’s largest electricity costs. MTR Paradise Mall and MTR Ocean Walk in Hong Kong and Big C in Thailand all use FRIGAID.
Hospitals
Round-the-clock cooling, cleaner cooling water and smoother-running standby generators.
Government buildings
Measurable, reportable energy and carbon savings.
Semiconductor fabs
In use at leading Asian wafer fabs, including TSMC and UMC.
PCB plants
Chillers and air compressors covered in one project.
Electronics manufacturing
In use at electronics plants across Asia, including Thailand.
Data centers
Data-hall cooling runs all year without stopping. FRIGAID® for the chillers, Zeta Power™ for the cooling towers, installed without a shutdown.
District cooling
A central chilled-water plant supplies several buildings, such as commercial complexes, hospitals and factories. FRIGAID® for the chillers, Zeta Power™ for the cooling towers.
Another type of facility?
If your building uses chillers, we offer a complimentary site assessment.
Results
Proven results
5–15%
Combined savings, both sides
Chiller electricity savings when FRIGAID® and Zeta Power™ are used together (manufacturer’s figure)
24,364,175kWh/year
TSMC
Saved in one year (2015 CSR report)
969,340kWh/year
UMC
Saved in one year across 8 chillers; cut 506 t CO2e
* The 5–15% figure comes from the manufacturer, Hsing Asia Pacific, based on analyses by user companies and research institutions; actual results depend on equipment condition.
Before and after installation
Zeta Power™Cooling-tower fill
Zeta Power™Chiller condenser tube sheet
FRIGAID® LubricantAir compressor power-analyzer readings before and after installation
Global clients of FRIGAID® & Zeta Power™
Semiconductor & electronics
- TSMC
- Intel
- Foxconn (Hon Hai)
- GlobalFoundries
- UMC
- Western Digital
- ASE
- Amkor
- Pegatron
- AUO
- Macronix
- Nanya Technology
- Powerchip
- VIS
- SPIL
- Unimicron
- KYEC
- ChipMOS
- Chipbond
- United Semiconductor
- JHICC
- Hana Microelectronics
- Lingsen Precision
- Unitech PCB
Wafers & materials
- Shin-Etsu
- Formosa Plastics
- GlobalWafers
- Siltronic
- Formosa SUMCO
- Nan Ya Plastics
- Formosa Chemicals & Fibre
- Wafer Works
Malls & retail
- MTR Malls (Hong Kong)
- Far Eastern SOGO
- Big C (Thailand)
- Citygate Outlets (Swire)
- Far Eastern Department Stores
- Far Eastern Big City (Hsinchu)
- TaiMall (Taoyuan)
- Walter Mart (Philippines)
- Plaza Tasek (Johor Bahru)
Hotels
- Holiday Inn Golden Mile (Hong Kong)
- Holiday Inn (Nashville)
- Novotel Bangkok Siam Square
- Mayfair Hotel (Shanghai)
- The Landis Taichung
- Evergreen Laurel Hotel (Keelung, Taichung)
- Grand Hi-Lai Hotel (Kaohsiung)
- Howard Prince Hotel (Taichung)
- Ocean Hotel (Hualien)
Hong Kong landmarks
- Hong Kong International Airport
- HSBC
- Hang Seng Bank
- PCCW
- Cyberport
- Towngas
- Hong Kong Central Library
- Hong Kong International School
- Tuen Mun Hospital
- Eastern Hospital
Contact us
Book a complimentary chiller plant site assessment
You are welcome to contact our team in Thailand.
6/1 Moo 11, Malaiman Rd., Wang Nam Khiao, Kamphaeng Saen, Nakhon Pathom 73140, Thailand